Item Total = $0.00 
Items = 0 
View Cart
United States
1-800-358-5525 or 
Welcome,
log in or register
 

Dynasonics TFX Ultra Transducer, for 2" and Larger ANSI/Copper Pipe

DYNASONICS  |   Item# DO-32617-50

$778.00 USD/EACH

Are you a reseller or buying in bulk? Call us today.


  • No need to shut down the process for installation or maintenance due to clamp-on sensor design
  • Bidirectional flow measurement system
  • Large, easy-to-read digital display
  • Rate and total backlit display
  • 4 to 20 mA output
  • RS-485 Modbus network connection
  • Remote totalizer reset
  • 0 to 1000 Hz rate pulse and dual alarm output
  • USB programming port with software included
  • Rugged, aluminum enclosure ensures a long service life in harsh environments
  • Totalizer options include forward, reverse, and net total
  • Use to measure clean liquids as well as those with small amounts of suspended solids or aeration
Order Flowmeter 32617-24 with your transducer for a complete system!
Ultrasonic flowmeters clamp onto the outside of pipes and do not contact the internal liquid. The technology has inherent advantages over alternate devices including low-cost installation, no pressure head loss, no moving parts to maintain or replace, no fluid compatibility issue, and a large, bidirectional measuring range that ensures reliable readings even at very low and high flow rates. Flowmeters are available in a variety of configurations — select a meter with features suitable to meet your particular application requirements.
Product Type Ultrasonic Flowmeters
Max flow rate (LPM) 1590
Max flow rate (GPM) 420
Wetted materials IP67-rated construction; CPVC, Ultem®, nylon cord grip, PVC cable jacket
Material (Housing) IP65 construction; powder-coated aluminum, polycarbonate, stainless steel, polyurethane, nickel-plated steel mounting brackets
Max operating temperature (º F) 250
Max operating temperature (º C) 121
Accuracy ±1% of reading or ±0.01 ft/sec (0.003 m/s), whichever is greater
Output 4 to 20 mA and RS-485 Modbus network connection
Pipe size 2" ANSI & Larger
Range Bidirectional to greater than 40 ft/sec (12 m/s)
Model DTTN-020-N-000-N
Qty/ea 1
Fluid Type Most clean liquids or liquids containing small amounts of suspended solids or gas bubbles
Enclosure rating IP65
CE Compliance Yes
Operating temperature -40 to 185 °F (-40 to 85° C)
Display Two-line LCD, LED backlight; top row 0.7 in. (18 mm) H, 7 segment ; botton row 0.35 in (9 mm) H
Make TFX ULTRA
Power 96 to 264 VAC, 47 to 63 Hz at 17 VA max
Brand DYNASONICS





Technical Resources
 
Service & Support
Still have questions
Contact Our Experts
for FREE product
application selection
and support.
or call 1-800-358-5525
Custom Ordering Solutions
Custom Ordering Solutions
Let us find the exact product you need. We have access to suppliers full lines - for products beyond what you see here. Call 1-800-358-5525
Questions and Answers

Do you have questions about this product?

Get answers from real customers and in-house experts with AnswerBox.

6 Questions | 6 Answers
Displaying questions 1-6
  • Q:

    Can this measure glycol flow in supply lines to a AC unit?
    Asked on 2/29/2016 by Ivan from New York

    1 answer

    • STAFF EXPERT

      A:

      This works with most clean liquids or liquids containing small amounts of suspended solids or gas bubbles.

      Answered on 2/29/2016 by Jen from Technical Support
  • Q:

    Our Community Well-House has a 4" or 6" Iron Pipe at the output to the users. Can I equip with this flow meter? DO-32617-50
    Asked on 8/13/2014 by Bill from Whidbey Island, WA, USA

    1 answer

    • STAFF EXPERT

      A:

      This is designed for use with ANSI pipe that is 2" or larger in diameter.

      Answered on 8/13/2014 by Jose from Technical Support
  • Q:

    Does it works on 2" copper pipe for water meter?
    Do this price ($690.64 CND/EACH) included everything? like meter and clams?


    Thanks
    Asked on 7/28/2014 by Glenn from British Columbia, Canada

    1 answer

    • STAFF EXPERT

      A:

      This item is designed to be used on copper pipes, 2" and larger. However, this is just the transducer. The meter itself is required for operation, item 32617-24.

      Answered on 7/29/2014 by Jay from Technical Support
  • Q:

    DO YOU SUPPLY THIS PRODUCE FOR 3/8" PTFE TUBING? WE ARE MEASURING NITRIC ACID 70%
    Asked on 7/26/2013 by wayne from columbus wi

    1 answer

    • STAFF EXPERT

      A:

      The smallest transducer option available is for a 1/2" OD in the ANSI version. Please refer to catalog number 32617-26.

      Answered on 7/26/2013 by Jose from Technical Support
  • Q:

    Will this meter work on Sch80 PVC pipe? I did not see PVC listed. Also just to confirm technology is this a transit time ultrasonic flow meter?
    Asked on 2/24/2013 by Jerry from Iowa

    1 answer

    • STAFF EXPERT

      A:

      This transit time ultrasonic flow meter works with copper pipe as well as ANSI schedule pipe, including Sch 80. Different transducers are used for the two pipe types however, so be careful how you specify the transducer.

      Answered on 2/26/2013 by Jon from Technical Support
  • Q:

    Will this unit work on stainless piping? I want to be able to validate flow on a Clean-in-Place (CIP) system while running the main alkaline wash cycle. Most of the tubing in my processing plants is between 2 and 3 inch 316 stainless.
    Asked on 2/7/2013 by Doug from OR

    1 answer

    • STAFF EXPERT

      A:

      As long as the SS pipe follows ANSI dimensions, yes. This unit comes with transducers for ANSI size pipes of Carbon, Alloy, and Stainless Steel pipes.

      Answered on 2/11/2013 by Jen from Technical Support
Displaying questions 1-6