Item Total = $0.00 
Items = 0 
View Cart
United States
1-800-358-5525 or 
Welcome,
log in or register
 

Vacuum regulator, 0 to 29" Hg, 2.47cfm

Item# DO-00910-10

$297.00 USD/EACH

Are you a reseller or buying in bulk? Call us today.


Product Type Compressor Regulators
Thread size 1/8" NPT(F); 1/8" NPT(F)
Wetted parts Brass
Port size 1/8" NPT(F); 1/8" NPT(F)
Qty/ea 1
Brand Cole-Parmer

Accessories
Qty/Price
Availability

at $32.75 $26.20 USD/EACH

Usually ships in 11 days.




Technical Resources
 
Service & Support
Still have questions
Contact Our Experts
for FREE product
application selection
and support.
or call 1-800-358-5525
Custom Ordering Solutions
Custom Ordering Solutions
Let us find the exact product you need. We have access to suppliers full lines - for products beyond what you see here. Call 1-800-358-5525
Questions and Answers

Do you have questions about this product?

Get answers from real customers and in-house experts with AnswerBox.

5 Questions | 5 Answers
Displaying questions 1-5
  • Q:

    Would this regulator be suitable to connect to a house vacuum system?
    Asked on 7/5/2011 by Anonymous

    1 answer

    • Staff Reviewer

      A:

      That depend on the overall flow of your house system. Please call us for further assistance.

      Answered on 7/6/2011 by Jen from Technical Support
  • Q:

    IS there a in and out line?
    Asked on 6/6/2011 by Anonymous

    1 answer

    • Staff Reviewer

      A:

      Yes, there is an inlet and outlet, both have 1/8" NPT threaded connections. The back connection is perpendicular to the one seen in the picture, and the reason it cannot be seen at the same time.

      Answered on 6/7/2011 by Jen from Technical Support
  • Q:

    I see only one 1/8 NPT connection, where is the other?
    Asked on 3/25/2011 by JZ from Chicago, IL

    1 answer

    • STAFF EXPERT

      A:

      It's on the other side of the regulator in the photo.

      Answered on 3/28/2011 by Jon from Technical Support
  • Q:

    I assume this works by "bleeding" room air into the vacuum stream. In my application I cannot contaminate the vacuum stream, is it possible to supply "clean", lighty pressurized air as the bleed stream through a connection to the regulator?
    Asked on 3/2/2010 by Anonymous

    1 answer

    • STAFF EXPERT

      A:

      That would be correct; the ambient atmosphere does enter the vacuum regulator through the small vent hole in the valve body. This ambient flow can be eliminated by plugging the vent hole, though the regulator may not return to a lower vacuum without a vent from the upstream side. You may try this by putting electrical tape over the vent to see how the regulator performs. If there are no problems the vent hole can be permanently plugged by pressing the vent filter in and Epoxying the vent hole. The gauge ports and the vent go to a common chamber. The regulator can achieve about ½”Hg. higher vacuum with the vent plugged.

      Answered on 3/5/2010 by Jen from Technical Support
  • Q:

    Can I use this vacuum regulator as normal pressure regulator? Or it can be used only for vacuum application? Thanks a head.
    Asked on 10/30/2009 by Abe Bae from College Park, MD

    1 answer

    • STAFF EXPERT

      A:

      This should only be used for vacuum applications.

      Answered on 10/30/2009 by Jen from Technical Support